Stainless Steel Biological Safety Cabinet

1 Piece (MOQ)

Business Type Manufacturer, Supplier
Material Stainless Steel
Finishing Powder Coated
Color Silver
Click to view more

Preferred Buyer From

Location Anywhere in India

Product Details

Condition
New
Power Supply
3 kW
Application
Protect Personnel, Products And The Environment From Exposure
Type
Biosafety Cabinets
Country of Origin
India
Noise
70db
Inflow Velocity
Minimum 100% From The Front Opening
Biosafety Level
BSL 1
Air Flow Direction
Horizontal

With the experience of about 5 years, we are becoming as one of the promising manufacturers and suppliers of Laboratory Biosafety Cabinet. It is extensively utilized in hospitals, research labs, and chemical & pharmaceutical industries. This cabinet is required for working with potentially harmful microorganisms to prevent them from contaminating the room or environment. Offered Laboratory Biosafety Cabinet is made according to three classes of biosafety levels as desired by the customer.


Biosafety Cabinet

SSI Class II Type B1 Biological Safety Cabinets

The Class II Type B1 biological safety cabinet has a common plenum from which 70% of air is exhausted, and 30% re-circulated to the work area as the down flow.


Type B1 cabinets also have a dedicated exhaust feature that eliminates re-circulation when work is performed towards the back within the interior of the cabinet. Toxic chemicals employed as an adjunct to microbiological processes should only be employed if they do not interfere with work when re-circulated in the down flow.

SSI Class II Type B2 Biological Safety Cabinets


SSI Class II Type B2 cabinet all inflow and down flow air is exhausted after HEPA filtration to the external environment without recirculation within the cabinet. Type B2 cabinets are suitable for work with toxic chemicals employed as an adjunct to microbiological processes under all circumstances since no re-circulation occurs. In theory, Type B2 cabinets may be considered to be the safest of all Class II biological safety cabinets since the total exhaust feature acts as a fail-safe in the event that the down flow and / or exhaust HEPA filtration systems cease to function normally. However, Class II Type B2 cabinets are, in practice, difficult to install, balance and maintain.